By the AeroKool Aviation team · Hialeah, Florida
Repair station inspection personnel are the employees a certificated repair station relies on to determine that an article is airworthy with respect to the work performed, before that article is approved for return to service. The regulation defines what those people have to be familiar with and proficient in, not which certificate they have to hold.
That distinction is the source of most confusion in supplier evaluation, and it becomes sharper the moment nondestructive inspection enters the picture, because part 145 names no NDT qualification standard anywhere. The requirements are distributed across several short sections of Subpart D and Subpart E, and each one carries a different obligation: familiarity and proficiency, supervision, training, recordkeeping, and the authority to sign.
Read one section in isolation and you will attribute a requirement to the wrong place, which is exactly how audit findings are created without any technical failure underneath them. This article maps the sections that actually apply, states plainly what three of them do not contain, and lists what to verify. The qualification program behind an inspector’s certification is the other half of the question, and the methods a component may be inspected with are its technical half.
What Repair Station Inspection Personnel Are Required to Be
The governing section is short enough to read in full, and reading it in full is the fastest way to stop assuming things that are not there.
§145.155 in Full
§145.155 has two paragraphs. The first requires the repair station to ensure that persons performing inspections are thoroughly familiar with the applicable regulations in the chapter and with the inspection methods, techniques, practices, aids, equipment and tools used to determine the airworthiness of the article on which maintenance, preventive maintenance or alterations are being performed, and proficient in using the various types of inspection equipment and visual inspection aids appropriate for the article being inspected. The second concerns the ability to understand, read and write English.
Two qualities, then: familiarity with the regulations and the methods, and proficiency with the equipment. Both are stated as conditions the station must ensure, which makes them an organizational obligation rather than a personal credential.
What the Section Does Not Contain
No named qualification standard. No level. No examination. No interval, and no currency requirement of any kind: the words current, currency and recent do not appear in it. The nearest thing to a recurring obligation anywhere in part 145 is a quality-manual procedure, discussed further below, and it is not a rule about the inspector’s vigency.
This matters because purchase specifications routinely assert a currency requirement under §145.155 that does not exist. Writing a requirement into a contract is legitimate. Attributing it to a section that does not contain it is not, and a supplier who points that out is reading the regulation correctly.
Nor does the section mention nondestructive testing. Searching part 145 for nondestructive, non-destructive, NDT, NDI, penetrant, magnetic particle, eddy current or radiographic returns one substantive result across Subparts C, D and E, and it is a rating rather than a personnel rule. Everything specific about an NDT inspector’s qualification therefore comes from somewhere other than the regulation, which is precisely why the quality manual is the document that answers the question.
The Roles Part 145 Distinguishes
Four distinct populations, four distinct sections, and conflating any two of them produces a finding.
Qualified Personnel and the Practical Test
§145.151 sets the baseline. Each certificated repair station must designate an employee as the accountable manager, provide qualified personnel to plan, supervise, perform and approve for return to service the maintenance it is rated for, ensure it has a sufficient number of employees with the training or knowledge and experience in the performance of maintenance, and determine the abilities of its noncertificated employees performing maintenance functions based on training, knowledge, experience or practical tests.
That last clause is where most NDT personnel actually sit, because neither part 65 nor part 145 issues an NDT method certificate. It is also the regulatory basis for a practical examination, which is worth knowing before assuming the examination requirement came from the industry standard alone.
Supervisors, and the Absence of a Ratio
§145.153 requires the station to ensure it has a sufficient number of supervisors to direct the work performed under the repair station certificate and operations specifications, and requires those supervisors to oversee the work performed by any individuals who are unfamiliar with the methods, techniques, practices, aids, equipment and tools used to perform the work. Inside the United States a supervisor must be appropriately certificated as a mechanic or repairman under part 65. Outside the United States the section allows eighteen months of practical experience, or training in and thorough familiarity with the methods, techniques, practices, aids, equipment and tools.
There is no numerical ratio in that section. The standard is a sufficient number, judged against the work performed, and a specification demanding one supervisor per some quantity of technicians is imposing a customer requirement rather than citing the rule.
Inspectors and Release Signatories, and Why the Line Is Geographic
§145.157 governs personnel authorized to approve an article for return to service. Inside the United States, each such person must be appropriately certificated as a mechanic or repairman under part 65. Outside the United States, the section allows a trained person, or eighteen months of practical experience, with thorough familiarity with the methods and proficiency in the use of the various inspection methods.
Read the structure of that division. It is geographic, not functional: the regulation does not distinguish between an inspector who reads a penetrant indication and one who reads a dimensional check, but it does distinguish between a station inside the United States and one outside it. The records that carry a finding through to the release sit downstream of whichever version applies.
The Repairman Route and the Former-Employee Rule
Two short sections that come up constantly in supplier files. §145.159 allows a repair station to recommend a person for certification as a repairman, provided that person is employed by the station and meets the requirements of §65.101. That route is how many inspection and release signatories at component shops obtain the part 65 certificate the release requires, and it ties the certificate to the employer: the recommendation comes from the station, for work at that station.
§145.160 restricts the employment of former FAA employees for a period of two years. It is short, it is absolute in its terms, and it is the kind of provision that gets missed until an auditor asks about a specific hire.
Neither section produces an NDT credential, and that is the point worth carrying away. A repairman certificate recommended under §145.159 authorizes work at the station that recommended it, within the ratings on the certificate; it says nothing about penetrant, eddy current or ultrasonic method qualification. A shop can therefore hold every part 65 certificate the release requires and still have no evidence that the person who read the indication was qualified in the method. The certificate answers the signature question. The program answers the method question.
The Inspection Act Itself
Everything above concerns who. This section concerns what has to happen, and it is where the most common misconception in the whole subject lives.
What §145.213 Requires
§145.213 requires the station to inspect each article upon which it has performed maintenance before approving that article for return to service. It provides that the station certifies on the maintenance release that the article is airworthy with respect to the work performed after an inspector inspects the article and determines it to be airworthy. It states, completely and in one sentence, that for the purposes of those paragraphs an inspector must meet the requirements of §145.155. And it provides that, except for individuals employed by a repair station located outside the United States, only an employee appropriately certificated as a mechanic or repairman under part 65 is authorized to sign off on final inspections and maintenance releases.
So the inspection authority and the signature authority are separate grants. A person can be fully qualified to inspect under §145.155 and still be unable to sign the release inside the United States, and an NDT Level III certification does not change that. Which level owns the method and which certificate signs the release are two different questions with two different answers.
What §145.213 Does Not Require
It contains no rule that the person who performed the work may not inspect it. That separation is widely applied and widely assumed to be regulatory, and it is not. Where a shop applies it, the requirement comes from that shop’s own quality control manual, which means it can neither be assumed at a supplier who never claimed it nor waived at a supplier whose manual does claim it.
Ask whether the separation exists and ask where it is written. One of those two answers is usually missing.
Rosters, Employment Summaries and the Five Business Days
§145.161 requires three rosters: management and supervisory personnel, the names of all inspection personnel, and the personnel authorized to sign a maintenance release for the repair station. It also requires a summary of the employment of each individual whose name appears on those rosters.
What the Summary Has to Show
Present title. Total years of experience and the type of maintenance work performed. Past relevant employment, with the names of employers and the periods of employment. Scope of present employment. And the type of mechanic or repairman certificate held, with the ratings on that certificate.
That summary is more useful to a customer auditor than any certificate, because it is where an experience claim becomes checkable against dates. It is also, reliably, the document found incomplete.
The Deadline Is an Update, Not a Retention
Within five business days of a change, the rosters required by that section must reflect it. That is the only interval the section contains: there is no retention period in §145.161. The two-year retention periods live in §145.163 for training records and in §145.219 for the records that demonstrate compliance with part 43, and attributing either of them to the roster section is a small error that signals how the manual was assembled.
Training Is Approved, Not Merely Acceptable
§145.163 requires a certificated repair station to have and use an employee training program approved by the FAA, consisting of initial and recurrent training, and requires the training records to be retained for a minimum of two years. Revisions to the program are submitted to the responsible Flight Standards office.
Read the verb. Much of part 145 requires arrangements to be acceptable to the FAA; the training program is approved by it, and its revisions are submitted. A supplier whose NDT training exists only as an internal syllabus outside the approved program has a gap that is easy to find and awkward to close, and the same applies to method training added after the program was last revised.
Where the Recurring Obligations Actually Live
If §145.155 has no interval and §145.161 has no retention, the recurring machinery has to be somewhere. It is in the quality control system.
The Nine Procedures of §145.211
§145.211 requires a quality control system acceptable to the FAA, requires repair station personnel to follow it, and requires a quality control manual, in a format acceptable to the FAA, containing procedures for a defined list. Three of them bear directly on inspection personnel: establishing and maintaining proficiency of inspection personnel; qualifying and surveilling noncertificated persons who perform maintenance, preventive maintenance or alterations; and performing final inspection and return to service of maintained articles.
The first of those is the home of every recertification interval, examination rule and proficiency demonstration a program contains. The second is how NDT personnel are governed at all, given that they hold no part 65 method certificate. The NDT procedures inside a quality control manual are therefore the document to request, and the FAA’s guidance for developing and evaluating those manuals is AC 145-9A, issued 6 October 2017.
The Sections That Set the Records Floor
§145.219 requires records in English demonstrating compliance with part 43, a copy of the maintenance release to the owner or operator, retention of those records for at least two years from the date the article was approved for return to service, and availability to the FAA and the NTSB. Separately, §145.221 requires the station to report to the FAA within ninety-six hours after it discovers any serious failure, malfunction or defect of an article. The term serious is not defined in that section, which makes the internal threshold a quality-system decision worth asking about.
Two years is a floor, not a policy. Customer contracts and operator programs frequently require longer, and the quality control measures behind a component repair are where that longer commitment has to be written down if it exists.
What to Verify in a Supplier’s Inspection Organization
- Who is on the inspection personnel roster, and when was it last updated relative to the last personnel change?
- Are the employment summaries complete for the people who will inspect and release this article?
- Which employees hold part 65 mechanic or repairman certificates, and which of them sign maintenance releases?
- Is NDT training inside the FAA-approved training program, and when was that program last revised?
- Which section of the quality control manual establishes and maintains proficiency of inspection personnel, and what interval does it set?
- How are noncertificated persons qualified and surveilled, and what evidence does that produce?
- Does the manual separate the person who performs the work from the person who inspects it, and where is that stated?
- What is the internal threshold for a serious failure, malfunction or defect under the ninety-six hour requirement?
A supplier that answers these from documents rather than from memory is describing a system. The regulatory compliance framework a repair station operates under is the context, and where nondestructive inspection is part of the scope, the limited rating that governs it has to be verified as well.
Frequently Asked Questions
what does part 145 require of inspection personnel?
Section §145.155 requires persons performing inspections to be thoroughly familiar with the applicable regulations and with the inspection methods, techniques, practices, aids, equipment and tools used to determine the airworthiness of the article, and proficient in using the inspection equipment and visual aids appropriate for it, plus the ability to understand, read and write English. It names no standard, level or interval.
does an inspector at a repair station need an A&P certificate?
To perform the inspection, §145.155 sets familiarity and proficiency requirements rather than a certificate requirement. To sign off on final inspections and maintenance releases inside the United States, §145.213 requires an employee appropriately certificated as a mechanic or repairman under part 65. The two acts have different requirements.
is there a required ratio of supervisors to technicians?
No. Section §145.153 requires a sufficient number of supervisors to direct the work performed under the certificate and operations specifications. Any numerical ratio comes from a customer requirement or an internal policy, not from the regulation.
can the person who did the work also inspect it?
Part 145 does not prohibit it. Section §145.213 requires the article to be inspected before return to service by an inspector meeting §145.155, and it contains no rule about who performed the work. Where a shop applies that separation, it comes from its own quality control manual, so the question is whether the manual says so.
how long must inspection personnel records be kept?
Training records are retained for a minimum of two years under §145.163(c), and the records demonstrating compliance with part 43 for at least two years from the date the article was approved for return to service under §145.219(c). Section §145.161 carries no retention period; it requires the rosters to reflect changes within five business days.
who qualifies NDT inspectors at a repair station?
The repair station, through its own program. Part 145 names no NDT qualification standard, and §145.211(c)(1) requires quality-manual procedures for establishing and maintaining proficiency of inspection personnel and for qualifying and surveilling noncertificated persons. The standard adopted, and its levels, come from the organization’s program and from customer contracts.
Read the sections separately and the picture stops being confusing: familiarity and proficiency in §145.155, roles in §145.151 through §145.157, rosters in §145.161, approved training in §145.163, and every recurring obligation in the quality control manual under §145.211. Ask for the manual section rather than the certificate, and check the roster date against the last personnel change.
About AeroKool Aviation. AeroKool Aviation is an FAA-certificated repair station in Hialeah, Florida, specializing in the repair and overhaul of environmental control system components — air cycle machines, cooling turbines, heat exchangers, refrigeration packages, valves and environmental control units — for commercial, regional, business jet, rotorcraft and military operators. The company was founded in 1959 and holds AS9110C and AS9100D registrations, with in-house PMA parts manufacturing and FAA DER repair engineering. Component capability is organized by aircraft category, manufacturer, model and component type in the component capability listing, down to individual part numbers such as this cooling turbine for a light business jet.
This article is general technical information about the personnel requirements that apply to inspection at a certificated repair station. It is not approved data, it is not a maintenance procedure, and it does not replace the component maintenance manual, structural repair manual, service bulletin, airworthiness directive or other airworthiness data your organization is approved to use. Regulations, advisory material and industry standards are revised, and the requirements that apply to a specific job depend on the article, the location of the station, the operator’s approved program and the scope of the repair station’s certificate. Verify the applicable requirements against the current regulatory text, your own quality control system, and your FAA principal inspector before performing or accepting any maintenance action.
Talk to AeroKool Aviation
AeroKool Aviation is an FAA-certificated repair station in Hialeah, Florida, overhauling air cycle machines, cooling turbines, heat exchangers, valves and environmental control units for commercial, regional, business and military operators since 1959, with an AS9110C quality system and in-house PMA and DER engineering. If you have a component on the bench, a repeat removal you cannot explain, or a part number you cannot source, we will tell you what falls inside our ratings and what does not. Request a quote with the part number and the condition you need resolved, and the answer will name the scope it falls under.
Address
1495 S.E. 10th Avenue Hialeah, FL 33010-5984
eMail
aerokool@aerokool.com | sales@aerokool.com
Phone
305.887.6912 | 800.458.4255