A large engine machine placed on a table, used for non-destructive testing methods.

NDT Methods Aircraft Components: What Each Method Finds and Who Is Qualified to Read It

By the AeroKool Aviation team · Hialeah, Florida

NDT methods aircraft components are inspected with fall into a short and stable list: visual, liquid penetrant, magnetic particle, eddy current, ultrasonic and radiographic. The decision that matters is which discontinuity a method can physically reach, not which instrument is newest on the bench.

Two conditions make that decision harder than a comparison table suggests. Every method is blind to an entire class of defect, so a clean result narrows the possibilities without eliminating them. And in the United States the qualification of the person who interprets the result rests on no national standard at all: AC 65-31B states plainly that “there is no national certification requirement or standard to determine that NDI personnel are qualified to accomplish NDIs.”

That sentence reorganizes the subject. If no national standard governs the inspector, the credibility of an inspection rests on the standard an employer adopted, the procedure it wrote, the equipment it calibrated and the records it kept. This guide covers what an NDT result decides, what each method reaches, how personnel are qualified in the absence of a national requirement, why nondestructive inspection is a limited rating rather than a service line, and where the obligations sit inside a repair station’s quality system.

What an NDT Result Actually Decides

An inspection produces a finding. It does not produce a decision, and treating the two as one thing is the most common structural error in component maintenance planning.

The finding describes what the method detected, in the vocabulary of the method. The decision is whether the article is serviceable, repairable or scrap, and that decision belongs to approved data — the component maintenance manual, the overhaul manual, the service bulletin or the repair data the organization is approved to use. An inspection tells you what is there. Approved data tells you what it means.

The Finding, the Disposition and the Release

Three separate acts, three separate records, and confusing them is what auditors find. The inspection generates a result against a written procedure. The disposition compares that result to the acceptance criteria in the manufacturer’s data for the part number. The release certifies that the article was inspected and found airworthy with respect to the work performed, which is the language 14 CFR §145.213 uses for the maintenance release.

A component can be inspected competently and still be released improperly. The chain runs from procedure to result to disposition to release, and a break at any link makes the last one indefensible. The records an NDT finding has to leave behind are the part of that sequence most often reconstructed after the fact rather than built as the work proceeds.

A clean report says that one method, applied by one person under one procedure, did not detect a discontinuity of the kind that method detects. It does not say the part is sound. A rotor released on a surface-method result alone has been cleared of surface indications and nothing else, and repeat removals frequently trace back to a report that answered a narrower question than the planner believed it had asked.

NDT Methods Aircraft Components Are Inspected With, Method by Method

Six families, each with a physical basis and each with a boundary. The boundary tells you what the second method has to cover.

Surface Methods: Penetrant and Magnetic Particle

Liquid penetrant testing finds discontinuities open to the surface, on materials that are not porous. Its results depend far more on process control — cleaning, application, dwell time, developer, lighting and the inspector’s eye — than on the equipment involved. Fluorescent penetrant inspection of aircraft components is a process, not a machine, which is why it is one of the most audited operations in a component shop.

Magnetic particle testing finds surface and slightly subsurface discontinuities, and it has a material limit that decides whether it is even a candidate. ASTM E1444/E1444M-26, the aerospace practice for magnetic particle testing, applies to ferromagnetic material. Aluminium is not ferromagnetic, and neither are the austenitic stainless steels common in air cycle machine hardware, so on much environmental control system hardware magnetic particle inspection was not rejected on merit. It was never available.

Subsurface Methods: Ultrasonic and Radiographic

Ultrasonic testing reaches into the volume of a part, which is why it carries so much of the load when the concern is a crack that has not yet surfaced. Its scope is narrower than its reputation. ASTM E2375-26a, the practice for ultrasonic testing of wrought products, covers wrought material with a thickness or cross section of 0.250 in. (6.35 mm) or greater, and was adopted in place of MIL-STD-2154. A thin-wall casting sits outside that practice, so the limits of ultrasonic inspection on components belong in the plan rather than in a report that comes back inconclusive.

Radiographic testing images internal features and tolerates complex geometry best, at the cost of access, exposure control, licensing and interpretation skill. It answers questions the other methods cannot reach, and it asks more of the organization that runs it than any other method on the list.

Eddy Current, and the Standard That Does Not Exist

Eddy current testing detects near-surface discontinuities and property changes in electrically conducting material, and on aluminium hardware it frequently does the work magnetic particle cannot. It also has a peculiarity worth knowing before a procedure is written: there is no general ASTM standard practice for eddy current testing. What exists is narrower — a guide for conformable sensor arrays, a practice for carbon steel welds, and one for seamless and welded tubular products in titanium and austenitic stainless steel.

The consequence is practical. Where penetrant and magnetic particle procedures can be anchored to an aerospace practice by designation, eddy current inspection of aircraft components usually has to be anchored to the manufacturer’s data and to a technique the organization qualified itself. The vocabulary at least is settled: ASTM E1316-26b is the standard terminology for nondestructive examinations, and it keeps “indication”, “discontinuity” and “defect” from being used interchangeably in a report where the difference is the whole point.

The National Qualification Standard That Does Not Exist

This is the fact most inspection-technology material omits, and it matters more than any capability on any equipment list.

What AC 65-31B Actually Says

AC 65-31B, issued 24 February 2014 and still current, addresses the training, qualification and certification of nondestructive inspection personnel, and lists part 145 among its related regulations. Two sentences in it carry the weight. The first is the absence quoted above. The second describes what fills it: “NDI organizations typically use multiple national or international standards to develop a training and qualification program.”

An inspector is therefore qualified according to a program the employer wrote, against a standard the employer selected, and audited by whoever the employer answers to. That is not a loophole. It is the system, and it means the question to ask a supplier is not whether its inspectors are certified but under which document, at which level, and by whom.

The Standards an Employer May Adopt

AC 65-31B names the standards the FAA considers acceptable for that purpose, and they are not interchangeable. NAS 410 is the aerospace sector document, published by the Aerospace Industries Association in the National Aerospace Standards library, where it appears as nondestructive test personnel certification. On the ASNT side the distinction is sharper than most procurement conversations acknowledge: SNT-TC-1A (2024) is a recommended practice that guides an employer in writing its own qualification program, ANSI/ASNT CP-189 (2024) is an American National Standard setting minimum requirements for employer-based certification, and ANSI/ASNT CP-9712 (2023) is the United States adoption of ISO 9712:2021, the third-party scheme. CP-105 (2024) supplies the topical outlines behind the training.

Two suppliers can both answer that their inspectors are certified while operating under documents of different force. Aerospace NDT personnel qualification is where a specific question separates a program from a claim.

What “Harmonized” Does Not Mean

AC 65-31B also accepts the European document, and the phrasing repays attention: it refers to prEN 4179 and notes that it “is now harmonized with AIA-NAS-410.” Harmonized is not identical, and it is not equivalent. Where a contract or an operator’s approved program calls out one of the two by name, the other does not automatically satisfy it. The label was never the problem. The named document is.

Level I, Level II and Level III as the FAA Describes Them

The level structure is where the qualification question becomes concrete, and the FAA’s own descriptions are the ones to use. AC 65-31B describes Level I personnel as performing specific tests, specific calibrations, specific interpretations and evaluations for acceptance or rejection. It describes Level II as setting up and standardizing equipment, conducting tests, and interpreting, evaluating and documenting results in accordance with procedures. It describes Level III as interpreting the codes, standards and other regulatory documents that control the methods the organization uses.

The jump that matters is the second one. Level II works inside procedures; Level III decides what the procedures say. A shop with certified Level II personnel and no Level III authority of its own depends on someone else to write and approve its techniques, which is a legitimate arrangement and a very different one. The difference between NDT Level II and Level III is the difference between executing a method and owning it.

Nondestructive Inspection Is a Limited Rating, Not a Service Line

This is the point where inspection stops being a technique and becomes a matter of certificate scope, and it is routinely missed in marketing copy about inspection technology.

The Capability List Is the Instrument

14 CFR §145.61 lists the limited ratings a repair station may hold, and paragraph (b)(9) is “Nondestructive inspection, testing, and processing.” It is the only substantive appearance of nondestructive inspection in part 145, and it changes the question. A repair station does not offer nondestructive inspection the way it offers a service; it either holds that limited rating or it does not.

Because the rating is limited, it carries the mechanism that goes with limited ratings. §145.215 provides that a certificated repair station with a limited rating may perform maintenance on an article only if the article is listed on a current capability list acceptable to the FAA or on the repair station’s operations specifications. How a capability list works, and what it commits a repair station to, is therefore not a separate compliance topic. It is the instrument through which an NDT rating is exercised, and the NDT limited rating under part 145 cannot be evaluated without it.

What to Verify Before the Component Ships

Read the ratings on the operations specifications, then ask whether the specific article appears on the capability list. A supplier that subcontracts the inspection is not disqualified by that arrangement. It is describing a different chain of responsibility, and the chain is what you are buying.

Industry accreditation sits alongside this and does not replace it. Nadcap accreditation for nondestructive testing, administered by the Performance Review Institute and governed by the Nadcap Management Council, is an industry-managed conformity assessment that many primes require by contract. It is a customer requirement, not a certificate scope. A supplier can be accredited and still be outside its rating for your part number.

Where NDT Obligations Live Inside the Quality System

The regulation governing inspection personnel is shorter than most people expect, and the substantive obligations sit in the quality control system. Knowing which document holds which duty makes a supplier audit efficient.

Proficiency of Inspection Personnel

§145.155 has two paragraphs. It requires inspection personnel to be thoroughly familiar with the applicable regulations and with the inspection methods, techniques, practices, aids, equipment and tools used to determine the airworthiness of the article, and proficient in using the various types of inspection equipment and visual inspection aids appropriate for the article being inspected. It names no standard, no level and no interval, and it contains no currency requirement.

The recurring obligation is elsewhere. §145.211 requires a quality control manual that includes procedures for “establishing and maintaining proficiency of inspection personnel,” which is where an organization’s chosen qualification standard, its examinations and its recertification intervals actually live. Training is separate again: §145.163 requires an employee training program approved by the FAA, initial and recurrent, with training records retained for a minimum of two years. Requirements for repair station inspection personnel are assembled from three sections that are easy to attribute to one.

Calibration of Measuring and Test Equipment

§145.109, which covers equipment, materials and data, requires that all test and inspection equipment and tools used to make airworthiness determinations be calibrated to a standard acceptable to the FAA. The same section requires the documents and data needed for the work — airworthiness directives, instructions for continued airworthiness, maintenance manuals, overhaul manuals, standard practice manuals, service bulletins and other data acceptable to or approved by the FAA — to be current and accessible when the relevant work is being done.

The interval is a quality-manual obligation: §145.211 requires procedures for calibrating measuring and test equipment, including intervals for calibration. One out-of-tolerance instrument can invalidate every result taken with it since the last verified check, which is why NDT equipment calibration requirements are audited backwards from the finding rather than forwards from the certificate on the wall.

Written Procedures and the Data That Must Be Current

An inspection that is not performed to a written procedure cannot be repeated, and a result that cannot be repeated cannot be defended. What an NDT written procedure has to contain is governed by the organization’s quality control manual, by the manufacturer’s data for the article, and by the standard the organization adopted. The FAA’s guidance for developing a nondestructive inspection organization is AC 25-29, issued 20 September 2013.

Note also what §145.213 does not contain. It requires that each article be inspected before it is approved for return to service, that an inspector meeting the §145.155 requirements make that determination, and that only an appropriately certificated mechanic or repairman sign off on final inspections and maintenance releases in the United States. It contains no rule that the person who performed the work may not inspect it. Where a shop applies that separation, and many do, it comes from the shop’s own quality control manual and NDT procedures, not from the regulation.

A Clean Inspection Is Not a Clean Part

Every method has a detection capability that varies with flaw size, geometry, material, access, technique and operator. Reporting a result as pass or fail hides that variability rather than resolving it.

Probability of Detection, and Why There Is No FAA Guidance on It

Probability of detection is the statistical treatment of that variability, and the tools for it are standardized. ASTM E2862-23 covers hit or miss data, where the response is binary and flaw size is the predictor. ASTM E3023-21 covers signal-response data, where the response is measurable and continuous. MIL-HDBK-1823A, the Department of Defense handbook on nondestructive evaluation system reliability assessment, is what the defence community built around the same question.

And there is no FAA advisory circular on probability of detection. Neither AC 65-31B nor AC 25-29 mentions it. That absence is why inspection intervals, sampling plans and disposition thresholds so often rest on an assumption nobody wrote down, and why probability of detection in nondestructive testing belongs in a fleet engineering conversation rather than a laboratory footnote.

What to Ask Instead of “Did It Pass”

Ask what the procedure was capable of detecting on that geometry, in that material, at that access. Ask what a second method would have added, and what the finding was before the disposition turned it into a verdict. A component can be inspected, documented, released and still carry the discontinuity that brings it back. No method eliminates that risk. Coverage planning reduces it.

Common Nonconformities in an NDT Program

The findings that surface repeatedly during supplier audits and after repeat removals are rarely exotic:

  • Inspection performed to a method rather than to a written procedure, with the technique reconstructed afterwards from memory.
  • A qualification standard named in the quality manual, and a certification record issued under a different one.
  • Recertification intervals defined nowhere, on the assumption that §145.155 imposes currency. It does not.
  • Calibration verified at the certificate rather than at the interval, so an out-of-tolerance condition surfaces without anyone knowing which results it touched.
  • Acceptance criteria taken from a general standard when the manufacturer’s data for the part number governs.
  • A method chosen for availability rather than for the discontinuity of concern, most often magnetic particle proposed on non-ferromagnetic hardware.
  • Rosters of inspection personnel not updated within the five business days §145.161 allows after a change.
  • Records kept informally, when §145.219 requires records demonstrating compliance to be retained for at least two years from the date the article was approved for return to service.

Questions to Ask Before You Send a Component Out for Inspection

  • Which limited ratings does the certificate carry, and does §145.61(b)(9) appear among them?
  • Is this article on the capability list or the operations specifications, and is that version current?
  • Which qualification standard governs the inspection personnel, at which level, and who issued the certification?
  • Is the inspection performed under your certificate or subcontracted, and if subcontracted, to whom and under whose procedure?
  • Which written procedure applies to this part number, and at what revision?
  • Which data defines the acceptance criteria, and is that revision current?
  • How are calibration intervals set, and what happens to prior results when an instrument is found out of tolerance?
  • What will the record show — indication, disposition, procedure revision and the identity of the inspector?

Frequently Asked Questions

is there a required certification for aircraft NDT inspectors in the united states?

No. AC 65-31B states that there is no national certification requirement or standard to determine that NDI personnel are qualified to accomplish NDIs, and describes organizations as using multiple national or international standards to build their own qualification programs. The standard, the level and the certifying party therefore have to be asked about specifically.

what is the difference between NAS 410 and SNT-TC-1A?

Publisher and force. NAS 410 is a National Aerospace Standard published by the Aerospace Industries Association and frequently invoked by contract. SNT-TC-1A is an ASNT recommended practice that guides an employer in writing its own program, and ANSI/ASNT CP-189 is the American National Standard that sets minimum requirements for employer-based certification. Both routes appear among the standards AC 65-31B accepts.

can one NDT method clear a component on its own?

Only for the class of discontinuity that method detects. Surface methods address discontinuities open to or near the surface; volumetric methods address the interior. A clean result from a single method narrows the possibilities without eliminating them, which is why coverage is planned as a set rather than chosen as a preference.

does a repair station need a special rating to perform NDT?

Nondestructive inspection, testing and processing is a limited rating under §145.61(b)(9), and §145.215 requires the article to be listed on a current capability list acceptable to the FAA or on the operations specifications before the work is performed. Verify the rating and the listing rather than the equipment.

how long do NDT records have to be kept?

Section §145.219 requires records demonstrating compliance with part 43 to be retained for at least two years from the date the article was approved for return to service, and §145.163 sets the same two-year minimum for training records. Customer contracts frequently require longer, so the regulatory minimum is a floor rather than a policy.

who decides whether an indication is acceptable?

The approved data for that part number, applied by qualified inspection personnel under the organization’s procedures. The inspection produces an indication and the manufacturer’s data defines what is acceptable; §145.213 then requires an inspector meeting the §145.155 requirements to determine airworthiness with respect to the work performed.


Inspection is a narrowing exercise, not a clearance. Choose the method for the discontinuity you are trying to find, verify the rating and the listing before the component ships, and read the record for what the procedure was capable of detecting rather than for the word at the bottom of the page.

About AeroKool Aviation. AeroKool Aviation is an FAA-certificated repair station in Hialeah, Florida, specializing in the repair and overhaul of environmental control system components — air cycle machines, cooling turbines, heat exchangers, refrigeration packages, valves and environmental control units — for commercial, regional, business jet, rotorcraft and military operators. The company was founded in 1959 and holds AS9110C and AS9100D registrations, with in-house PMA parts manufacturing and FAA DER repair engineering. Component capability is organized by aircraft category, manufacturer, model and component type in the component capability listing, down to individual part numbers such as this cooling turbine for a light business jet.

This article is general technical information about nondestructive inspection methods, personnel qualification and inspection records for aircraft components. It is not approved data, it is not a maintenance procedure, and it does not replace the component maintenance manual, structural repair manual, service bulletin, airworthiness directive or other airworthiness data your organization is approved to use. Regulations, advisory material, industry standards and manufacturer data are revised, and the requirements that apply to a specific inspection depend on the part number, the material, the aircraft, the operator’s approved program and the scope of the repair station’s certificate. Verify the applicable requirements against the current manufacturer data, your own quality control system and its written procedures, and your principal inspector or Level III authority before performing or accepting any inspection.

Talk to AeroKool Aviation

AeroKool Aviation is an FAA-certificated repair station in Hialeah, Florida, overhauling air cycle machines, cooling turbines, heat exchangers, valves and environmental control units for commercial, regional, business and military operators since 1959, with an AS9110C quality system and in-house PMA and DER engineering. If you have a component on the bench, a repeat removal you cannot explain, or a part number you cannot source, we will tell you what falls inside our ratings and what does not. Request a quote with the part number and the condition you are trying to resolve, and the answer will name the scope it falls under.

Address 1495 S.E. 10th Avenue Hialeah, FL 33010-5984 eMail aerokool@aerokool.com | sales@aerokool.com Phone 305.887.6912 | 800.458.4255

Scroll to Top

Have Questions Or Need Information?

Please fill out the form below to contact us and we will get back to you as soon as possible.
Request a Quote
Choose one for Sales and Repair Services
We're committed to your privacy. AeroKool Aviation uses the information you provide to us to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, check out our Privacy Policy.

Looking for parts?

You can search by Part Number or Aircraft Model

Search for Parts

Browse our extensive inventory

Note: You can search by part number

Your Aircraft

Browse our extensive inventory

Note: You can search by aircraft name