By the AeroKool Aviation team · Hialeah, Florida
Aerospace NDT personnel qualification is the documented process by which an employer establishes that a named person may perform, interpret and sign a specific nondestructive inspection method at a specific level. It is a program an employer wrote against a standard the employer adopted, not a national license somebody carries from job to job.
That is not an interpretation. AC 65-31B, the FAA advisory circular on the training, qualification and certification of nondestructive inspection personnel, states that in the United States “there is no national certification requirement or standard to determine that NDI personnel are qualified to accomplish NDIs,” and describes what organizations do instead: they “use multiple national or international standards to develop a training and qualification program.”
Every practical question about inspection credibility follows from that sentence. If the standard is chosen rather than imposed, then a certification card means nothing until you know which document it was issued under, at which level, for which method, and by whom. This article covers what qualification establishes, the standards available to establish it, what part 145 actually requires of inspection personnel, and the questions that separate a program from a claim. The NDT methods a component may be inspected with are the other half of the same evaluation.
What Aerospace NDT Personnel Qualification Actually Establishes
Qualification does not establish that someone is good at inspection. It establishes that an organization has evidence, in a defined form, that a person meets criteria the organization published in advance.
Training, Qualification and Certification Are Three Different Things
Training is instruction, delivered against a syllabus. Qualification is the demonstrated combination of training, experience and examination results that satisfies the criteria in the organization’s program. Certification is the written attestation that the qualification was achieved, issued by the party the program names.
Collapsing the three is the most common error in supplier files, and it produces a specific audit finding: a training certificate presented as a certification, with no examination record and no experience log behind it. A course attendance record proves attendance.
Certification Belongs to a Program, Not to a Person
Under an employer-based scheme, certification is issued by the employer and it does not travel. When an inspector changes companies, the new employer evaluates the prior qualification against its own program and issues its own certification, or does not. Under a third-party scheme the certificate is issued by a certification body and is portable in a different sense, but the employer still has to authorize the person to work to its procedures.
The consequence for a component owner is direct. A supplier cannot answer the qualification question by naming an individual’s credential. It answers by naming its program.
Why There Is No National Requirement to Point At
The absence is not an oversight, and understanding why it exists prevents a bad assumption from being written into a purchase specification.
What AC 65-31B Says and Does Not Say
AC 65-31B was issued on 24 February 2014, it remains current, and it lists part 145 among its related regulations. It provides guidance on developing training and qualification programs, it describes the levels, and it names the standards the FAA considers acceptable for the purpose. What it does not do is impose one.
Guidance is not a rule. The advisory circular describes acceptable means, and an organization that follows a different acceptable means is not out of compliance with anything. That is why the question to ask is never “are your inspectors FAA certified for NDT.” There is no such certificate.
What Fills the Gap
Three layers, and all three have to be present for an inspection to be defensible. The organization adopts a recognized qualification standard. It writes a program that implements the standard, including examinations, experience requirements and recertification intervals. It keeps records that show, for each person and each method, that the program was followed.
Any one of those layers missing breaks the chain, and the break is invisible until an auditor or a warranty dispute pulls on it. Records are what make the other two layers real.
The Standards an Organization May Adopt
AC 65-31B names the documents the FAA accepts for building a qualification program, and they are not equivalent to each other. Treating them as interchangeable is how two suppliers give the same answer while operating under different obligations.
The Aerospace Sector Route
NAS 410 is the National Aerospace Standard for nondestructive test personnel certification, published by the Aerospace Industries Association, which maintains the National Aerospace Standards library and lists the document under nondestructive test personnel certification. It is the route most often invoked by contract in aerospace work, because primes and airframers flow it down to their supply chains rather than leaving the choice open.
Note the publisher. NAS standards are AIA documents, and attributing NAS 410 to another standards body is the kind of error that tells an auditor how carefully the quality manual was written.
The ASNT Documents and Their Different Force
On the ASNT side the distinction matters more than most procurement conversations acknowledge. SNT-TC-1A (2024, with addendum) is a recommended practice: it gives an employer guidance for writing its own in-house qualification and certification program. ANSI/ASNT CP-189 (2024) is an American National Standard that sets minimum requirements for employer-based certification and builds on SNT-TC-1A. ANSI/ASNT CP-9712 (2023) is the United States adoption of ISO 9712:2021, the third-party certification scheme. ANSI/ASNT CP-105 (2024) supplies the topical outlines that define the body of knowledge behind the training.
A program built on a recommended practice and a program built on an American National Standard are both acceptable to the FAA, and they are not the same commitment. The difference between NAS 410 and SNT-TC-1A is where a supplier evaluation stops being a paperwork exercise.
The European Document and the Word “Harmonized”
AC 65-31B also accepts the European document, referring to prEN 4179 and noting that it “is now harmonized with AIA-NAS-410.” Harmonized is not identical and it is not equivalent. Where a customer specification, a contract or an operator’s approved program names one of the two, the other does not automatically satisfy it. The advisory circular also lists ATA Specification 105, ISO 9712, CAN/CGSB-48.9712-95 and MIL-STD-410E, which it describes as acceptable although now rescinded.
The label was never the problem. The document named in the contract is.
What Part 145 Requires, and What It Does Not Name
Here is the part that surprises people who expect the regulation to settle the question. It does not name a single qualification standard.
§145.155 in Full
§145.155 has two paragraphs. It requires inspection personnel to be thoroughly familiar with the applicable regulations and with the inspection methods, techniques, practices, aids, equipment and tools used to determine the airworthiness of the article, and proficient in using the various types of inspection equipment and visual inspection aids appropriate for the article being inspected. The second paragraph concerns understanding, reading and writing English.
That is the whole of it. No named standard, no level, no examination, no interval, and no currency requirement. Searching part 145 for nondestructive testing produces one substantive result, and it is a rating rather than a personnel rule.
Where Proficiency Actually Lives
The recurring obligation sits in the quality control system. §145.211 requires a quality control manual, in a format acceptable to the FAA, that includes procedures for “establishing and maintaining proficiency of inspection personnel.” That is the hook on which an organization’s chosen standard, its examinations and its recertification intervals hang, which is why the NDT procedures inside a quality control manual are the document to ask for rather than the certificate on the wall.
The same section requires procedures for “qualifying and surveilling noncertificated persons who perform maintenance, preventive maintenance, or alterations,” which is where most inspection personnel sit, since neither part 65 nor part 145 issues an NDT certificate.
§145.151 sits underneath both. It requires a certificated repair station to provide qualified personnel to plan, supervise, perform and approve for return to service the maintenance it is rated for, to ensure it has a sufficient number of employees with the training or knowledge and experience in the performance of maintenance, and to determine the abilities of its noncertificated employees performing maintenance functions based on training, knowledge, experience or practical tests. That last clause is the regulatory basis for a practical examination, and it is worth reading before assuming an examination requirement came from the industry standard alone. The broader set of obligations on inspection personnel at a repair station is assembled from several sections that are easy to attribute to one.
The Training Program Is Approved, Not Merely Acceptable
§145.163 requires a certificated repair station to have and use an employee training program approved by the FAA, consisting of initial and recurrent training, with training records retained for a minimum of two years. Revisions go to the responsible Flight Standards office.
Read the verb carefully. Much of part 145 requires things to be acceptable to the FAA; the training program is approved by it. A supplier whose NDT training is described only in an internal syllabus, outside the approved program, has a gap that is easy to find and awkward to close.
Qualification Is Method-Specific and Level-Specific
A qualification is never general. It attaches to one method, at one level, and frequently to a defined scope of parts or techniques within that method.
One Method at a Time
Fluorescent penetrant qualification says nothing about eddy current, and eddy current qualification says nothing about ultrasonics. A supplier that describes its people as NDT certified without naming methods has told you the category, not the capability, and the methods are where the answer lives — penetrant and eddy current test different physics with different training behind them.
Scope narrows further inside a method. A certification may name techniques, equipment families, material groups or product forms, and a program that limits a person to the techniques they were examined on is stricter than one that does not. Neither is a nonconformity by itself, but the difference decides whether the person who signs your report was examined on the technique the report describes.
An inspector can be competently qualified and still be the wrong person for your part. Method coverage is the check.
The Level Question
The level determines what a person may decide rather than what they may touch. AC 65-31B describes Level I as performing specific tests, specific calibrations, specific interpretations and evaluations for acceptance or rejection; Level II as setting up and standardizing equipment, conducting tests, and interpreting, evaluating and documenting results in accordance with procedures; and Level III as interpreting the codes, standards and other regulatory documents that control the methods the organization uses.
That last one is an authority, not a seniority label. Whether a shop holds its own Level III authority or borrows one changes who writes the technique your part is inspected under, and it is a legitimate arrangement either way as long as it is stated.
Certification Records: What Has to Exist
Qualification that cannot be evidenced is indistinguishable from qualification that never happened, and the regulation is specific about part of the evidence.
The Roster and the Five Business Days
§145.161 requires a roster of management and supervisory personnel, a roster listing the names of all inspection personnel, and a roster of personnel authorized to sign a maintenance release. The rosters must reflect changes within five business days of the change.
Note what that section is and is not. It is a currency requirement for the roster, not for the inspector, and it carries no retention period of its own. The two-year retention periods live in §145.163(c) for training records and §145.219 for the records that demonstrate compliance with part 43.
What the Employment Summary Has to Show
The same section requires a summary of the employment of each person on those rosters: present title, total years of experience and the type of maintenance work performed, past relevant employment with the names of employers and periods of employment, scope of present employment, and the type of mechanic or repairman certificate held with its ratings.
That summary is more useful to a customer auditor than any certificate, because it is where experience claims become checkable. It is also the document most often found incomplete.
Some of the file is not yours to read, and knowing the boundary makes an audit go faster. Examination papers and personnel records carry privacy and test-security constraints, so a reasonable supplier will show the program, the standard, the interval, the certification record and the roster while redacting or summarizing the rest. A refusal to name the standard is a different matter. That one is not confidentiality.
Common Nonconformities in a Qualification Program
The findings repeat across audits, and none of them are exotic:
- A standard named in the quality manual, and certification records issued under a different one.
- Training certificates on file with no examination results and no experience log behind them.
- Recertification intervals undefined, on the assumption that §145.155 imposes currency. It does not.
- Vision examination requirements described in the adopted standard but not evidenced in the file.
- Personnel certified for a method but working to a technique outside the scope their certification names.
- Inspection personnel roster not updated within the five business days §145.161 allows.
- NDT training delivered outside the FAA-approved training program required by §145.163.
- A Level III function performed by an outside consultant with no written agreement defining what that person approves.
How to Verify a Supplier’s Qualification Program
Eight questions, in the order that makes the answers hard to blur:
- Which qualification standard does your program adopt, at which revision, and where is it referenced in the quality manual?
- Is certification employer-based or issued by a third-party body, and which body?
- For the method that will inspect this article, who is certified, at what level, and when was that certification issued?
- Who performs your Level III function, and if it is external, what does the agreement authorize that person to approve?
- How are examinations administered and recorded, and who grades them?
- What are your recertification intervals, and what triggers requalification outside them?
- Is NDT training part of the FAA-approved training program, and may the relevant section be reviewed?
- May the inspection personnel roster and the employment summaries be reviewed as part of the audit?
A supplier with a real program answers these in order and reaches for files. The certifications and approvals a repair station publishes are the starting point of that conversation, not the end of it.
Frequently Asked Questions
is there an FAA certification for NDT inspectors?
No. AC 65-31B states that there is no national certification requirement or standard to determine that NDI personnel are qualified to accomplish NDIs. Part 65 issues mechanic and repairman certificates, and neither is an NDT method certification. Qualification comes from a program the employer built on an adopted standard.
who issues an NDT certification?
Either the employer, under an employer-based scheme such as a program written to SNT-TC-1A or CP-189, or a third-party certification body under a scheme such as ISO 9712 and its United States adoption CP-9712. Both routes appear among the standards AC 65-31B accepts, and the two produce documents with different portability.
does an NDT certification transfer to a new employer?
Under an employer-based scheme, no. The new employer evaluates the prior training, experience and examination evidence against its own program and issues its own certification. Under a third-party scheme the certificate itself remains valid, and the employer still has to authorize the person to work to its procedures.
what does part 145 require of inspection personnel?
Section §145.155 requires inspection personnel to be thoroughly familiar with the applicable regulations and the inspection methods, techniques, practices, aids, equipment and tools used to determine airworthiness, and proficient in using the inspection equipment and visual aids appropriate for the article. It names no standard and no interval. The recurring obligations sit in §145.211 and §145.163.
how often does NDT personnel qualification have to be renewed?
The interval comes from the standard the organization adopted and the program it wrote, not from part 145. Section §145.155 contains no currency requirement, and §145.211(c)(1) makes establishing and maintaining proficiency of inspection personnel a quality-manual procedure. Ask for the interval in writing.
what records prove NDT qualification?
The certification record itself, the examination results behind it, the documented training, the experience log, the vision examination the adopted standard requires, and the roster and employment summary that §145.161 requires. Training records are retained for a minimum of two years under §145.163(c), and customer contracts frequently require longer.
Qualification is a documentation discipline before it is a technical one. Ask which standard, at which revision, for which method, at which level, and read the examination and experience evidence rather than the certificate, because the certificate is the only part of the file that was designed to be shown.
About AeroKool Aviation. AeroKool Aviation is an FAA-certificated repair station in Hialeah, Florida, specializing in the repair and overhaul of environmental control system components — air cycle machines, cooling turbines, heat exchangers, refrigeration packages, valves and environmental control units — for commercial, regional, business jet, rotorcraft and military operators. The company was founded in 1959 and holds AS9110C and AS9100D registrations, with in-house PMA parts manufacturing and FAA DER repair engineering. Component capability is organized by aircraft category, manufacturer, model and component type in the component capability listing, down to individual part numbers such as this heat exchanger for a widebody platform.
This article is general technical information about the qualification of nondestructive inspection personnel and the records that evidence it. It is not approved data, it is not a maintenance procedure, and it does not replace the component maintenance manual, structural repair manual, service bulletin, airworthiness directive or other airworthiness data your organization is approved to use. Regulations, advisory material and industry qualification standards are revised, and the requirements that apply to a specific inspection depend on the method, the article, the customer specification, the operator’s approved program and the scope of the repair station’s certificate. Verify the applicable requirements against your own quality control system, the current revision of the standard your program adopts, and your principal inspector or Level III authority before performing or accepting any inspection.
Talk to AeroKool Aviation
AeroKool Aviation is an FAA-certificated repair station in Hialeah, Florida, overhauling air cycle machines, cooling turbines, heat exchangers, valves and environmental control units for commercial, regional, business and military operators since 1959, with an AS9110C quality system and in-house PMA and DER engineering. If you have a component on the bench, a repeat removal you cannot explain, or a part number you cannot source, we will tell you what falls inside our ratings and what does not. Request a quote with the part number and the condition you need resolved, and the answer will name the scope it falls under.
Address
1495 S.E. 10th Avenue Hialeah, FL 33010-5984
eMail
aerokool@aerokool.com | sales@aerokool.com
Phone
305.887.6912 | 800.458.4255