By the AeroKool Aviation team · Hialeah, Florida
NDT limited rating Part 145 authorizes a certificated repair station to perform nondestructive inspection, testing and processing on the articles it has listed, and on nothing beyond them. It is a scope of authorization, not a description of the equipment in the building.
The rating exists in one place. 14 CFR §145.61 sets out the ratings the FAA issues to repair stations, and among the limited ratings, paragraph (b)(9) is “Nondestructive inspection, testing, and processing.” That is the only substantive appearance of nondestructive inspection in part 145: search the regulation for penetrant, magnetic particle, eddy current or radiographic and nothing comes back.
So the regulation says almost nothing about how the work is done and everything about who may do it and to what. This article covers what the rating authorizes, why a limited rating cannot be evaluated without the capability list, what the rating does not cover, and how to read a supplier’s answer. The methods themselves are a separate question with a separate set of documents behind it.
What the NDT Limited Rating Part 145 Actually Authorizes
Read the phrase in the regulation carefully, because it is broader than most people assume in one direction and much narrower in another.
Inspection, Testing and Processing
The rating covers three activities, not one. Inspection and testing are what most people mean by NDT. Processing is the part that gets overlooked, and it matters in a component shop, because the preparatory and post-inspection operations a method requires are part of the work being authorized rather than incidental to it.
The breadth stops there. Holding the rating does not authorize the station to disassemble, repair or overhaul the article it inspects, and holding an accessory or limited component rating does not by itself authorize nondestructive inspection as a service to others. Ratings are granted, not implied.
The wording also says nothing about method. It does not enumerate penetrant, magnetic particle, eddy current, ultrasonic or radiographic testing, and it does not distinguish between them. Which methods a station may actually apply, and to what, is settled downstream: by the equipment and data requirements it can satisfy, by the personnel its program authorizes, by the procedures its quality manual carries, and by the articles it has listed. The rating opens the door. Four other documents decide what walks through it.
The Rating Attaches to Articles, Not to Techniques
This is the point that reorganizes the whole subject. A limited rating is limited by reference to the articles it covers, so the question “does this shop hold an NDT rating” is incomplete. The complete question is whether the rating covers the article you are sending.
A shop can hold the rating, own the equipment, employ qualified personnel and still be outside its authorization for your part number. That is not a technical failure. It is a scope failure, and it is invisible from a website.
Class Ratings and Limited Ratings Are Different Instruments
Part 145 issues ratings in two families, and the difference decides how much homework a customer has to do.
Why a Class Rating Is Self-Describing
A class rating describes a category of article, and a station holding one may work within that category subject to its manual, its equipment and its data. The scope is legible from the certificate itself, which is why class-rated work is easier to evaluate at a distance.
Why a Limited Rating Is Not
A limited rating is defined by a list rather than by a category, so the certificate alone does not tell you what the station may touch. Two stations with identical wording on their certificates can have entirely different authorized scopes, and the difference lives in a document the certificate points to rather than in the certificate.
That is why an NDT rating cannot be assessed from the certificate. The certificate tells you the rating exists. The list tells you what it reaches.
Underneath both sits §145.201, which sets the privileges and limitations of a repair station certificate and is the section a representation of capability is measured against. It is the reason marketing language matters here in a way it does not in other industries: a public claim that reaches past the ratings and the list is not merely optimistic, it describes work the station is not authorized to perform. Where a customer relies on that claim and ships a part, both parties have a problem, and the one holding the certificate has the larger share of it.
The Capability List Is How a Limited Rating Is Exercised
Here is the mechanism, and it is worth quoting because it is the operative sentence for every limited rating.
The Operative Requirement
§145.215 provides that a certificated repair station with a limited rating may perform maintenance, preventive maintenance and alterations on an article only if the article is listed on a current capability list acceptable to the FAA or on the repair station’s operations specifications.
Two acceptable instruments, then: the operations specifications, or a capability list the FAA finds acceptable. Neither is optional, and a statement about owning the equipment is not a third option.
What “Current” and “Acceptable” Are Doing in That Sentence
Current means the list has to reflect what the station may do now, not what it once demonstrated. Acceptable to the FAA means the list is subject to the agency’s evaluation rather than being an internal marketing document. The combination is what gives the list its force, and it is also what makes a stale list a finding rather than a formality.
Ask for the list with its revision date, and ask when the article you are shipping was added to it. How a capability list works and what it commits a repair station to is the companion question to this one, and the two are answered from the same file.
Self-Evaluation Is Part of the Deal
Adding an article to a capability list is not a paperwork act. The station has to establish that it has the housing, equipment, materials, data, trained personnel and procedures for that article before the entry is made, and the record of that evaluation is what an auditor asks to see. A list with entries and no evaluations behind them is a list of intentions.
Two of those elements are worth naming because they are where NDT entries fail. §145.109 requires the station to have the equipment, tools and materials necessary for the work, requires all test and inspection equipment used to make airworthiness determinations to be calibrated to a standard acceptable to the FAA, and requires the documents and data needed for the work — including maintenance manuals, overhaul manuals, standard practice manuals and service bulletins — to be current and accessible when the work is being done. §145.103 requires housing for the facilities, equipment, materials and personnel consistent with the ratings and limitations held.
An entry made without the current data for that article is the most common quiet failure, because nothing about it is visible until someone asks which revision of the manual defined the acceptance criteria. Data currency is a scope question, not a filing question.
What the NDT Rating Does Not Cover
Four things the rating is regularly assumed to include, and does not.
It Does Not Name a Personnel Standard
Part 145 nowhere names NAS 410, SNT-TC-1A, CP-189, ISO 9712 or any other qualification standard. The rating authorizes the activity; the competence of the people performing it comes from a program the organization wrote against a standard it adopted, and from customer requirements flowed down by contract. How aerospace NDT personnel qualification actually works is therefore a separate line of questioning from the rating, and both have to be satisfied.
It Does Not Confer Release Authority for Someone Else’s Work
Inspecting an article and approving an article for return to service are different acts with different requirements. The rating supports the first. The second brings in the inspection and signature requirements of Subpart D and Subpart E: §145.155 sets what an inspector must be familiar with and proficient in, and §145.213 requires the article to be inspected before it is approved for return to service and restricts the signature, inside the United States, to an employee appropriately certificated under part 65. So which level owns the method while a part 65 certificate signs the release is a distinction that catches people out regularly.
It Does Not Supply the Acceptance Criteria
The rating authorizes the activity and says nothing about what an indication means. The disposition of a finding comes from the approved data for that part number — the component maintenance manual, the overhaul manual, the service bulletin or the repair data the organization is approved to use — and no rating, accreditation or personnel certification substitutes for it.
That separation is worth holding on to, because it is what keeps an inspection result from becoming an opinion. The method finds the indication. The data decides the article. An article can be inspected under a valid rating, by qualified people, with calibrated equipment, and still be dispositioned against a superseded revision.
Subcontracted NDT: Whose Rating Applies
Most component shops do not perform every method in house, and subcontracting is entirely normal. The question is where the authorization sits.
Two Legitimate Structures
A station may hold the NDT rating and perform the work itself, or it may send the work to another organization and control that arrangement through its quality system. §145.211 requires quality-manual procedures for qualifying and surveilling noncertificated persons who perform maintenance, preventive maintenance or alterations, and that is the machinery through which outside inspection work is governed.
Neither structure is better in the abstract. What matters is that the structure is stated, that the surveillance is evidenced, and that the article’s release traces back to a defensible chain.
The surveillance obligation is more concrete than the word suggests. Qualifying an outside source means establishing, before the first order, what its scope, procedures, personnel program and calibration control actually are. Surveilling it means having a defined basis for continued use: audits, performance data, findings and their closure, and a rule for what happens when the source changes its own procedure. The FAA’s guidance for developing and evaluating quality control manuals, AC 145-9A of 6 October 2017, is the reference point for how those procedures are written, and it mentions nondestructive testing only in passing, as an example of recurring work that may be performed away from the station’s fixed location.
What Goes Wrong
The failure mode is a hybrid nobody wrote down: work sent out informally, on a purchase order that names a method and no procedure, returned as a certificate with no technique reference, and folded into a release package as though it had been performed under the station’s own rating. The chain is only as strong as the link nobody audits, and this is that link.
How to Read a Supplier’s Answer
Suppliers answer this question in a small number of recognizable ways, and each answer tells you where to look next.
The Answers That Are Complete
A station that names the rating, produces the operations specifications, shows the capability list with a revision date and points to your article on it has answered fully. A station that says the method is subcontracted, names the supplier and shows the surveillance record has also answered fully, and in some respects more usefully.
The Answers That Are Not
References to advanced equipment, brand names of instruments, photographs of a laboratory, or a statement that inspection happens at every checkpoint. None of those is a rating and none of them is a scope. Equipment is not authorization, and a brochure is not a capability list. The label was never the problem.
Common Nonconformities Around the Rating
- A capability list with no revision date, or a revision date older than the last change in scope.
- Articles on the list with no self-evaluation record behind the entry.
- A method performed in house for which the personnel program authorizes nobody at the required level.
- Subcontracted inspection with no surveillance record and no procedure named on the purchase order.
- Marketing material describing a capability broader than the rating and the list support.
- A release package that presents subcontracted inspection as work performed under the station’s own rating.
- Customer requirements flowed down to an order that never reached the quality manual or the subcontractor.
Questions Before You Send the Component
- Which ratings appear on the operations specifications, and does §145.61(b)(9) appear among them?
- Is the article on the current capability list, and what is that list’s revision date?
- When was the article added, and what self-evaluation supported the entry?
- Which methods are performed in house and which are subcontracted?
- For a subcontracted method, who performs it, under whose procedure, and what surveillance record exists?
- Which document defines the acceptance criteria for the inspection, and is that revision current?
- Who signs the final inspection and the maintenance release, and under which part 65 certificate?
- What will the release package contain when the article returns?
Those questions are answered from documents or they are not answered. The broader picture of what an FAA-certificated repair station is gives the context, and the records the inspection has to leave behind close the loop when the component comes back.
Frequently Asked Questions
what is an NDT limited rating under part 145?
It is the limited rating listed at §145.61(b)(9) as “Nondestructive inspection, testing, and processing.” It authorizes a certificated repair station to perform that activity on articles listed on its current capability list or its operations specifications, under §145.215.
does a repair station need a rating to perform NDT on its own articles?
Nondestructive inspection performed as part of maintenance the station is otherwise rated to perform is a different situation from offering nondestructive inspection as a service on articles it does not otherwise work on. The scope question is decided by the operations specifications and the capability list, so the correct move is to read those rather than to reason from the activity.
how do you know whether a part number is covered by the rating?
Ask for the current capability list and look for the article, or ask for the operations specifications if the scope is defined there. Section §145.215 requires the article to be listed on one or the other before the work is performed, so a supplier who cannot show either has answered the question.
does Nadcap accreditation extend a repair station’s rating?
No. Nadcap accreditation for nondestructive testing is an industry-managed conformity assessment that customers require by contract. It assesses processes against industry criteria and it neither issues ratings nor changes the scope of a certificate. A supplier can be accredited and still be outside its rating for a given article.
can NDT be subcontracted?
Yes, and it commonly is. The station retains responsibility through its quality system, and §145.211 requires quality-manual procedures for qualifying and surveilling noncertificated persons who perform maintenance. The arrangement has to be documented, and the surveillance has to leave a record.
where are the NDT procedures required to be written down?
In the quality control manual. Section §145.211 requires a quality control manual, in a format acceptable to the FAA, containing procedures for the items it lists, including establishing and maintaining proficiency of inspection personnel and calibrating measuring and test equipment. What those NDT procedures have to contain is where the rating turns into a working system.
Treat the rating as the first question and the list as the real one. A certificate establishes that the authorization exists; the current capability list, with its revision date and the evaluation behind your article’s entry, establishes that it reaches the component in your shipping crate.
About AeroKool Aviation. AeroKool Aviation is an FAA-certificated repair station in Hialeah, Florida, specializing in the repair and overhaul of environmental control system components — air cycle machines, cooling turbines, heat exchangers, refrigeration packages, valves and environmental control units — for commercial, regional, business jet, rotorcraft and military operators. The company was founded in 1959 and holds AS9110C and AS9100D registrations, with in-house PMA parts manufacturing and FAA DER repair engineering. Component capability is organized by aircraft category, manufacturer, model and component type in the component capability listing, down to individual part numbers such as this air cycle machine for a regional jet.
This article is general technical information about repair station ratings, capability lists and the scope of authorization for nondestructive inspection. It is not approved data, it is not a maintenance procedure, and it does not replace the component maintenance manual, structural repair manual, service bulletin, airworthiness directive or other airworthiness data your organization is approved to use. Regulations and advisory material are revised, and the requirements that apply to a specific job depend on the article, the rating held, the contents of the operations specifications and capability list, and the operator’s approved program. Verify the applicable requirements against the current regulatory text, the repair station’s own operations specifications and quality system, and your FAA principal inspector before performing or accepting any maintenance action.
Talk to AeroKool Aviation
AeroKool Aviation is an FAA-certificated repair station in Hialeah, Florida, overhauling air cycle machines, cooling turbines, heat exchangers, valves and environmental control units for commercial, regional, business and military operators since 1959, with an AS9110C quality system and in-house PMA and DER engineering. If you have a component on the bench, a repeat removal you cannot explain, or a part number you cannot source, we will tell you what falls inside our ratings and what does not. Request a quote with the part number and the work you need done, and the answer will name the scope it falls under.
Address
1495 S.E. 10th Avenue Hialeah, FL 33010-5984
eMail
aerokool@aerokool.com | sales@aerokool.com
Phone
305.887.6912 | 800.458.4255