By the AeroKool Aviation team · Hialeah, Florida
Nadcap NDT accreditation is an industry-managed assessment of a supplier’s nondestructive testing processes against criteria the aerospace industry writes for itself. It is a customer requirement, not a scope of regulatory authorization, and confusing the two is how a supplier evaluation reaches the wrong conclusion twice: once by accepting an accreditation as authority it never conferred, and once by rejecting a capable supplier that no customer ever asked to be accredited.
The program is administered by the Performance Review Institute and governed by the Nadcap Management Council, an industry body in which the aerospace primes and government participants set the requirements, decide what accreditation demands and manage the auditing. Nondestructive testing is one of its commodity programs, which is why the term shows up so often in aerospace purchase orders and quality clauses.
Nothing in that arrangement touches the regulation. A repair station’s authority to perform nondestructive inspection comes from 14 CFR §145.61, where paragraph (b)(9) lists “Nondestructive inspection, testing, and processing” among the limited ratings, and from the articles it has listed. This article separates the three systems that get conflated here, states plainly which parts of the accreditation criteria are publicly verifiable and which are not, and gives the questions that make an accreditation claim useful. The methods themselves sit underneath all three.
What Nadcap NDT Accreditation Is, and What It Is Not
Accreditation is a conformity assessment: an independent audit of a process against a written set of industry criteria, resulting in a status that customers recognize.
It Assesses Processes, Not Articles
The unit of assessment is the special process — the method, its controls, its personnel arrangements, its equipment and its records — rather than a part number. That is a real strength, because a process assessed well is assessed for every part that passes through it. It is also the source of the most common misreading, because a process assessment says nothing about whether a specific article is inside a supplier’s authorized scope.
The phrase special process is doing real work in that sentence. A special process is one whose result cannot be fully verified by examining the finished part afterwards, so confidence has to come from controlling the process itself. Nondestructive inspection belongs in that family for an unusual reason: what is being controlled is not a change to the part but the reliability of a decision about it. Nothing downstream reveals that an inspection missed something, which is precisely why the process, the equipment, the personnel and the records are audited instead of the outcome.
That also explains what an accreditation audit spends its time on. Written procedures and their approval, personnel qualification records, equipment and reference standard control, and the traceability that links a result to the conditions under which it was produced — the same subjects §145.211 requires a quality control manual to carry, examined against industry criteria rather than against the regulation.
It Is a Customer Requirement, Not a Regulatory One
No section of part 145 requires accreditation of any kind. The requirement arrives through contracts: a prime, an airframer or an operator names it in a quality clause, and the supplier either holds the status or does not win the work. That is a legitimate and useful mechanism, and it is enforced by the customer rather than by the authority.
A supplier can be fully compliant with part 145 and unaccredited. A supplier can be accredited and outside its ratings for your article. Both statements are true at once, which is why the two questions have to be asked separately.
Accreditation, Certification and Rating Are Three Different Things
Three systems, three issuing bodies, three things proved. Keeping them apart is most of the work.
The Rating: What the Authority Authorizes
The FAA issues ratings. §145.215 provides that a repair station with a limited rating may perform maintenance on an article only if the article is listed on a current capability list acceptable to the FAA or on the operations specifications. That is a scope of authorization, and nothing else on this page can widen it. What the NDT limited rating authorizes and how the capability list governs it is the first question in any evaluation.
The Quality System Registration: What the Registrar Attests
AS9110 for maintenance organizations and AS9100 for manufacturing are quality management system standards, and a registration against either is issued by a registrar under an accreditation scheme. It attests that a management system meets a standard. It is not an approval of any product, any repair or any inspection result, and presenting it as one is a category error that appears constantly in supplier literature.
The Special Process Accreditation: What the Industry Assesses
Nadcap sits in the third slot. It assesses the special process against industry-written criteria, on the industry’s schedule, for the industry’s own purposes. It says nothing about the certificate scope and nothing about the article list.
Why Primes Require It
The reason is worth understanding, because it explains what the status is actually good for.
One Audit Instead of Many
Before industry-managed accreditation, every prime audited every special-process supplier separately, against its own interpretation of the same requirements. The result was cost on both sides and inconsistency in the middle. A single accreditation, governed by the primes collectively, replaces a stack of duplicated audits with one assessment they all recognize.
What That Buys the Customer, and What It Does Not
It buys consistency of process assessment across a supply chain, on a recurring cycle, with findings that have to be closed. It does not buy a judgement about a specific article, a specific part number or a specific release, because those are not what was assessed. Consistency is not coverage.
There is a second thing it buys that is easy to overlook: a rhythm. An accreditation cycle imposes an external date on a supplier’s process controls, and external dates are what keep procedures, calibration registers and personnel files from quietly ageing. Shops that hold the status often run tighter systems than the criteria require, simply because something arrives on a schedule to look at them. That benefit is real, and it is a benefit of being audited rather than of the certificate.
What it cannot buy is the thing customers most want to read into it. An accreditation is not a warranty on any individual inspection, and a supplier in good standing can still produce a bad result on a Tuesday. The status raises the probability that the system behind the result was sound. It does not certify the result.
What Accreditation Does Not Replace
Three things, and each of them has to be verified separately whatever the accreditation status says.
The Rating and the Capability List
Accreditation does not extend a repair station’s ratings and does not add articles to a capability list. Where the article is not listed, §145.215 is not satisfied, and an accreditation certificate on the wall does not change that sentence.
Nor does it substitute for the equipment and data requirements the regulation imposes. §145.109 requires all test and inspection equipment used to make airworthiness determinations to be calibrated to a standard acceptable to the FAA, and requires the manuals, service bulletins and other data needed for the work to be current and accessible while the work is being done. An accreditation audit will look at much the same ground, on its own criteria and its own cycle, and the regulatory obligation stands whatever that audit concluded.
Accreditation does not touch who may inspect or who may sign, either. §145.155 sets what an inspector must be familiar with and proficient in, and §145.213 requires the article to be inspected before it is approved for return to service, restricting the signature inside the United States to an employee appropriately certificated under part 65. Those are grants from the authority and no industry program can widen them.
The Personnel Qualification Program
Accreditation does not issue personnel certifications. Individual qualification still comes from the program the employer wrote against a standard it adopted, in an environment where, as AC 65-31B states, “there is no national certification requirement or standard to determine that NDI personnel are qualified to accomplish NDIs.” Which standard that is — and the difference between NAS 410 and SNT-TC-1A is not cosmetic — has to be asked about directly, and the qualification program behind it is what the answer rests on.
The Approved Data That Defines Acceptance
Accreditation does not supply acceptance criteria. The disposition of an indication comes from the approved data for that part number: the component maintenance manual, the overhaul manual, the service bulletin or the repair data the organization is approved to use. A process can be accredited, performed by qualified people, on calibrated equipment, and still be dispositioned against a superseded revision. The method finds the indication. The data decides the article.
What Is and Is Not Publicly Verifiable About the Criteria
This section exists because the honest answer is unusual, and knowing it saves a wasted afternoon.
The audit criteria documents that define what a Nadcap NDT audit examines are distributed through the program’s own supplier-facing system rather than published openly, so their numbering, structure and content are not verifiable from public sources. Any article that recites specific criteria document numbers and their contents is either quoting from a licensed copy or repeating something it did not check. Neither is a basis for a purchase decision.
What is verifiable in public is the shape of the thing: that the program exists, that nondestructive testing is one of its commodity programs, that it is administered by the Performance Review Institute, and that the requirements are set and governed by the industry council rather than by a regulator. Everything specific about the audit itself has to come from the supplier’s own accreditation documentation, which the supplier can show you.
So ask for the certificate and read it, rather than reasoning from what the criteria are assumed to contain. It will state the scope of the accreditation, and the scope is the part that matters.
How to Use an Accreditation Claim in a Supplier Evaluation
Read the Scope, Not the Status
An accreditation has a scope: which processes, which methods, at which location. A supplier accredited for one method at one facility is not accredited for another method at another facility, and a claim that says only that the supplier is accredited has omitted the operative detail. Ask which methods and which site, then check that both match the work you are placing.
The site question deserves particular attention in a group with more than one legal entity or more than one plant. Accreditation attaches to a facility, and so does a repair station certificate. A group that holds both at one location and neither at another has not extended anything to the second address, and the same caution applies to equipment claims: a capability described for one plant is a claim about that plant. Reading a group’s material as though it described a single organization is one of the easier mistakes to make from the outside.
Check the Currency and the Findings Cycle
Status has an expiry and an audit cycle behind it. Ask when the last audit was, when the status expires, and whether any findings remain open. A supplier in good standing answers all three from a file. The certifications and approvals a repair station publishes are the starting point, and the accreditation documentation is the specific thing to request.
Open findings are worth asking about without suspicion, because findings are a normal output of any real audit. What matters is the closure record: what was found, what changed, when, and how the change was verified. A supplier that describes a finding and its closure clearly is showing you a working corrective action system, which is more informative than a clean sheet. A supplier whose audits never find anything is either exceptional or lightly examined, and the file will tell you which.
Two adjacent systems complete the picture, and both are verifiable independently of any accreditation: what the equipment calibration program has to demonstrate, and the written procedure that governs the specific method.
Common Misconceptions
“Nadcap Accreditation Means They Are Approved for NDT”
Approved by whom, for what. The FAA authorizes through ratings and the capability list; the industry assesses processes through accreditation. A supplier can hold the accreditation and still be outside its authorized scope for a given article, which makes the rating question the one to ask first.
“Accredited Personnel Do Not Need a Qualification Standard”
Accreditation does not certify individuals. Personnel qualification remains an employer program built on an adopted standard, with examinations, experience and records behind it, and the accreditation audit examines whether that program exists and is followed rather than replacing it.
“If They Are Not Accredited, They Cannot Do the Work”
Not as a regulatory matter. Accreditation is a contractual requirement, so the correct question is whether your own customer requirements flow it down to this order. Where they do, it is mandatory for you. Where they do not, an unaccredited supplier with the right rating, the right listing, the right personnel program and the right procedures is a legitimate choice.
Questions to Ask Before You Rely on the Claim
- Which methods and which facility does the accreditation cover, and may the certificate be reviewed?
- When was the last audit, when does the status expire, and are any findings still open?
- Which ratings appear on the operations specifications, and does §145.61(b)(9) appear among them?
- Is the article on the current capability list, and what is that list’s revision date?
- Which qualification standard governs the inspection personnel, at which level, and who certified them?
- Which written procedure applies to this part number, at what revision, and who approved it?
- Which data defines the acceptance criteria, and is that revision current?
- Do our own customer requirements flow an accreditation down to this order, and was that clause accepted?
The last question is the one most often skipped, and it is the only one on the list that determines whether accreditation is mandatory in your case at all. The quality control manual sections behind the process are where the rest of the answers live.
Frequently Asked Questions
is Nadcap accreditation required by the FAA?
No. No section of part 145 requires accreditation of any kind. It is an industry-managed program, required by customers through contracts and quality clauses rather than by the authority, and its absence is not a regulatory deficiency.
does Nadcap accreditation extend a repair station’s ratings?
No. Ratings are issued by the FAA, and §145.215 requires an article to be listed on a current capability list acceptable to the FAA or on the operations specifications before a station with a limited rating performs maintenance on it. Accreditation assesses processes and changes neither the rating nor the list.
who runs the Nadcap program?
It is administered by the Performance Review Institute and governed by the Nadcap Management Council, an industry body in which primes and government participants set the requirements and manage the program. That governance is what makes it an industry-managed conformity assessment rather than a regulatory one.
does accreditation certify NDT personnel?
No. Personnel qualification comes from the employer’s program built on an adopted standard such as NAS 410, SNT-TC-1A or the ASNT American National Standards, or from a third-party certification scheme. An accreditation audit looks at whether that program exists and is followed.
can an unaccredited supplier perform NDT on my component?
As a regulatory matter, yes, provided the station holds the rating, the article is listed, the personnel are qualified under its program and the procedures and data are current. As a contractual matter, it depends entirely on whether your customer requirements flow an accreditation down to the order.
what should the accreditation certificate be checked for?
Scope and currency. Which processes and methods it covers, which facility it applies to, when it expires, and whether findings from the last audit are closed. A claim without a scope is not a claim about your work.
Ask the rating question first, the accreditation question second, and never let the second answer the first. Accreditation tells you that a process was assessed against industry criteria; the operations specifications and the capability list tell you whether the supplier is authorized to touch your article at all.
About AeroKool Aviation. AeroKool Aviation is an FAA-certificated repair station in Hialeah, Florida, specializing in the repair and overhaul of environmental control system components — air cycle machines, cooling turbines, heat exchangers, refrigeration packages, valves and environmental control units — for commercial, regional, business jet, rotorcraft and military operators. The company was founded in 1959 and holds AS9110C and AS9100D registrations, with in-house PMA parts manufacturing and FAA DER repair engineering. Component capability is organized by aircraft category, manufacturer, model and component type in the component capability listing, down to individual part numbers such as this air cycle machine for a single-aisle platform.
This article is general technical information about industry accreditation for nondestructive testing and how it relates to repair station authorization. It is not approved data, it is not a maintenance procedure, and it does not replace the component maintenance manual, structural repair manual, service bulletin, airworthiness directive or other airworthiness data your organization is approved to use. Regulations, industry criteria and customer requirements are revised, and the requirements that apply to a specific order depend on the article, the ratings held, the contract and the operator’s approved program. Verify the applicable requirements against the current regulatory text, the supplier’s own accreditation and certificate documentation, and your own customer requirements before placing or accepting the work.
Talk to AeroKool Aviation
AeroKool Aviation is an FAA-certificated repair station in Hialeah, Florida, overhauling air cycle machines, cooling turbines, heat exchangers, valves and environmental control units for commercial, regional, business and military operators since 1959, with an AS9110C quality system and in-house PMA and DER engineering. If you have a component on the bench, a repeat removal you cannot explain, or a part number you cannot source, we will tell you what falls inside our ratings and what does not. Request a quote with the part number and the customer requirements that apply to it, and the answer will name the scope it falls under.
Address
1495 S.E. 10th Avenue Hialeah, FL 33010-5984
eMail
aerokool@aerokool.com | sales@aerokool.com
Phone
305.887.6912 | 800.458.4255